What was found
ADM#N162SY-5352 - DENT MEASURES 2.275" LONG X 1.164" WIDE X 0.025 DEEP. NOMINAL THICKNESS IS 0.0393" AND W/D IS 46.60. LOCATED EXTERNAL LH, ZONE 100, FCBS 53-10-00-004, FORWARD FUSELAGE SKIN PANEL, FR10 TO FR11, STRG15L TO STRG17L. (C-CHECK RO 7/14/2024) REPAIRED 2 EA DENTS BETWEEN FR 10-11 STGR 15L-17L. REF ETD2024-170-017737. NO WEIGHT AND BALANCE CHANGE REQUIRED DUE TO REPAIR PARTS WEIGHING LESS THAN 2.5 LBS. SEE CONTINUATION FOR WORK PERFORMED.EXTERNAL LOW FREQUENCY EDDY CURRENT [*], NDT PART 6 TASK 51-06-00-250-806-A, THRESHOLD= 20,667 FC OR 27,487 FH, WHICHEVER OCCURS FIRST, INTERVAL: 20,667 FC OR 27,487 FH, WHICHEVER OCCURS FIRST. THE EXTERNAL SDE SHALL BE ACCOMPLISHED BY MEANS OF A LOW FREQUENCY EDDY CURRENT (LFEC) IN ORDER TO DETECT A CRACK ON THE SKIN UNDER THE DOUBLER. THIS IS AN ADDITIONAL AND SPECIFIC INSPECTION REQUIREMENT.