What was found
COMPLY WITH REPAIR AUTHORIZATION: RA92795-ETD2024-170-019819 MXCODEID76651-PR - SKIN DAMAGE ON FORWARD FUSELAGE SKIN FR18-FR19 AND STGR 21R- STGR22R. PER ETD ETD2024-170-019819 PERFORM PERMANENT REPAIR. DUE AT 14559 CYCLES , PART NUMBER: , SERIAL NUMBER: , POSITION: (FILED CLOSED) COMPLIED WITH PERMANENT REPAIR ON FORWARD FUSELAGE SKIN FR18-FR19 AND STGR 21R- STGR22R IN REFERENCE TO ERJ SRM 53-10-01/REPAIR12P PER THE SRM THIS PEREMANENT REPAIR HAS RE-INSPECTION REQUIREMENTS:LOWFREQUENCYEDDY CURRENT (SDI ) FOR SINGLE DOUBLER:NDTPART6 TASK51-06-00-250-805-A INSPECTION THRESHOLD: 20667 FC OR 27487 FH WHICHEVER OCCURS FIRSTINSPECTION INTERVAL: 20667 FC OR 27487 FH WHICHEVER OCCURS FIRSTCURRENT FC: 14450 CURRENT FH: 24926.90INSPECTION DUE AT : 35117 FC OR 52413.90 FH