What was found
CENTER FUSELAGE T CAP CORRODEDIN MULTIPLE LOCATIONS ON LBL9 BETWEEN APPROXIMATELY F697.00 AND FS841.00 AS MARKED (C-CHECK RO 8/11/2024) BLENDED CORROSION FROM MULTIPLE LOCATIONS ON LBL9 T-CAP FLOOR STRUCTURE BETWEEN FS697 AND FS841. REPAIRED T-CAP REF REO 670-53-41-678 REV -A DATED 2024-07-22 AND CRJ-700 SRM 51-42-06-001-001-A01. RESTORED FINISH. COMPLIED WITH TASK CARD 51-900-1002-SKY AND MAJOR REPAIR(M-337 FORM) CHECKS GOOD. SEE CONTINUATION CARD FOR DETAILS.