What was found
FOUND CORRODED SUPPORT FITTING ON LOWER FRAME FLANGE AT FS.863 JUST RH OF STGR.27 (C-CHECK RO 12/21/2024) (FILED OPEN)REMOVED CORROSION FROM THE AFT MACHINED FITTING (SUPPORT FITTING) AT FS863.00 STGR27 PER CRJ700SRM 51-21-06-001-001-A01 AND FOUND NO ALLOWABLE DAMAGE FOR FITTINGS. REMOVED AND INSTALLED 1EA NEW AFT MACHINED FITTING AT FS863.00 STGR27 PER CRJ700SRM 51-42-21-001-001-A01 AND DWG SH670-37280 REV E. PRESSURE CHECK GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY. SEE CONTINUATION FOR DETAILS.