What was found
COCK PIT FLOOR CROSSBEAM FR11 HAS CORROSION ON TOP FLANGE AT CENTERLINE AREA (C-CHECK RO 9/26/2024) PERFORMED PERMANENT DOUBLER REPAIR ON COCKPIT FLOOR FR 11 CROSSBEAM REF. ETD2024-170-023439. CHANGE IN WEIGHT 195.32 GRAMS CAL. TOOL I.D.# SH2-10286, DUE DATE 4-22-25. SEE CONTINATION CARD FOR FURTHER WORK PERFORMED.THIS REPAIR DOES NOT ADVERSELY AFFECT A FATIGUE CRITICAL STRUCTURE AND DOES NOT REPRESENT AN AIRWORTHINESSLIMITATION. NO SPECIFIC OR ADDITIONAL INSPECTIONS ARE NECESSARY.