What was found
MULTIPLE GOUGES/SCRATCHES FOUND ON THE EXTERIOR, AFT OF FS559.00 +112 BETWEEN STRG 22R AND STRG 23R, JUST AFT OF THE LOW AIR GROUND CONNECTION ACCESS DOOR. (MARKED WITH TAPE) (FILED OPEN) COMPLIED WITH REO 601R-53-61-8244 DATED: 2024-10-26 REV - TEMPORARY DISPOSITION FOR BLENDED GOUGE DAMAGE TO FUSELAGE SKIN BETWEEN FS574.00 - FS605.00 & STR 21R €“ STR 26R (LP DOOR CUTOUT). PERFORMED A UT THICKNESS MEASUREMENT OF THE REWORKED AREAS IN REFERENCE WITH THE CRJ-200 NDTM PART 4 51-00-001. ALL MEASUREMENTS NOTED IN REO TABLES. PERFORMED AN EDDY CURRENT INSPECTION OF THE REWORKED AREAS IN REFERENCE WITH THE CRJ-200 NDTM PART 6 53-00-096. NO CRACKS NOTED AT THIS TIME. SEE CHILD CAMP FOR LEAK CHECK. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. ENTERED INTO ALLOWABLE DAMAGE MAPPING DATABASE ADM#N246PS-9119. APPLIED YELLOW DOT. COMPLIED WITH M-257.