What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE: RA74310-670-54-22-037 N787SK MXCODEID59647-PR - ENLARGED HOLES, LOG NUMBER 56115, LINE NO. 11. PERFORMED TEMPORARY REPAIR OF ENLARGED HOLES BY ACCOMPLISHING INSTRUCTIONS IN REO 670-54-22-037,. FINAL HOLE IS 0.354. INSTALLED SLIDER TRACK INSERT REPAIR IS ACCEPTABLE FOR 8000 FLIGHT HOURS AND REQUIRES DETAILED VISUAL INSPECTION PER NDTM 51-20-009 AT EVERY 1000 FLIGHT HOURS. , PART NUMBER: CN624-0101-003 - REVERSER GA-THRUST UPR LH, SERIAL NUMBER: SB1096, POSITION: ONLY (C-CHECK RO 11-6/2024) ENSURED FREEZE PLUG IS INTACT ON FWD HOLE AT LH TR I/B UPPER SLIDER TRACK AND COMPLIED TO ALL THE STEPS PROVIDED REF REO 670-54-22-037 REV -A DATE: 2024-10-01 PERMANENT REPAIR PROCEDURE. COMPLIED WITH TASK CARD 51-900-1002-SKY. SEE CONTINUE CARD FOR DETAILS.