Service difficulty report · Door Sill · Cndair CL6002B19

Difficulty date
September 27, 2024
Submitted
November 15, 2024
Operation
Air carrier
Aircraft
N246PS
Make and model
Cndair CL6002B19
Aircraft serial
7920
Aircraft time
42,342 hours, 41,768 cycles
Part
Door Sill
Condition
Corroded
Location
Zone 200
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

COMPLY WITH SCHEDULED MAINTENANCE CODE: RA54264-601R-53-41-666 N246PS MXCODEID49635-DTI - L/H FLOOR SILL FROM FS409+128 TO FS559 HAS CORROSION IN SEVERAL NUT PLATE HOLES. REPAIRED IAW REO 601R-53-41-66, REV C, DATED 11/06/2012. DVI BLENDED AREA OF FLOOR SILL PANEL PER NDTM 51-20-09 PART 1. REINSPECTED THE L/H PRESSURE FLOOR SILL FROM FS 409+128 - FS 559.00 AND FOUND SURFACE CORROSION ON PREVIOUS BLENDS BETWEEN LBL 36.00 - LBL 45.0 ON SEVERAL NUTPLATE HOLES/ON THE SILL PANEL. REPAIRED THE AREA IN REFERENCE WITH REO 601R-53-41-666 DATED: 2012-11-06 REV- C. PERFORMED UT THICKNESS MEASUREMENT OF THE BLENDED AREAS IN REFERENCE WITH THE NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS OF THE REO TABLES 1 & 2. PERFORMED AN EDDY CURRENT INSPECTION OF THE REWORKED AREA IN REFERENCE WITH THE NDTM PART 6 53-00-096. NO CRACKS NOTED AT THIS TIME. COMPLETED THE CORROSION FINDINGS REPORT. COMPLIED WITH TASK CARD 51-900-1003-SKY.