As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION NOTED ON FLOOR SUPPORT STRAP AT FS559 BTWN RBL27-R/H FLOOR SILL (MARKED) (C-CHECK RO 10/26/2024) (FILED CLOSED)REMOVED, LOCATED AND DRILLED NEW FLOOR SUPPORT STRAP AND INSTALLED NEW FLOOR SUPPORT STRAP AT FS559 BTWN RBL27-R/H FLOOR SILL REF CRJ200 SRM 51-42-06 AND DWG NO 601R31025 REV -N AND COMPLIED WITH SKYWEST TASKCARD 51-900-1003-SKY AND FORM M-337.