What was found
BIRD STRIKE DAMAGE TO UPPER SKIN PANEL (DWG: CC670-33105 REF), UPPER ELEC. BAY DOOR (DWG: CC670-33070 REF) AND UNDERLYING STRUCTURE (FRAME FS 193 (DWG: CC670-34201 REF) & STRINGER STR 14L (DWG: CC670-33145 REF)), LOCATED BETWEEN FS 193.00 - FS 202.75 AND STR 13-17 €“ LHS. COMPLIED WITH PERMANENT SPLICE REPAIR TO FRAME FS193 AT BL0 IN REFERENCE TO REO 670-53-11-2023 REV- - DATED 2024-12-10. REPLACED LHS SKIN PANEL AT FS193.00 TO 202.75 IN REFERENCE TO REO 670-53-11-2030 REV -- DATED 2024-12-10 AND SRM 51-42-00. REPLACED STRINGER STR 14L IAW SRM 51-42-00 SEE TASK CARD 51-900-1002-SKY AND MAJOR REPAIR M-337. SEE CP 29305118 FOR LH UPPER ELEC. BAY DOOR REPAIR.