Service difficulty report · Door Frame · Cndair CL6002C10
FAA SDR system
- Difficulty date
- September 27, 2024
- Submitted
- December 24, 2024
- Operation
- Air carrier
- Make and model
- Cndair CL6002C10
- Aircraft serial
- 10090
- Aircraft time
- 40,308 hours, 30,497 cycles
- Part
- Door Frame
- Condition
- Corroded
- Location
- Zone 100
- Stage of operation
- IN
- How discovered
- O
- Nature of condition
- O
- Precautionary procedure
- K
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FORWARD EQUIPMENT BAY DOOR SURROUND STRUCTURE, INTERCOSTALS FOR STRINGERS 25 RT AND 26RT CORRODED AT ATTACH POINTS ON FS 364, FORWARD FRAME. (C-CHECK RO 12/21/2024) (FILED OPEN)REPLACED FS364 FRAME SECTION REF DWG SH670-32050 REV. J, CRJ700 SRM 51-42-06-001-001-A01, CRJ700 SRM 53-21-23-201-008-A01. LEAK CHECK GOOD. COMPLIED WITH 51-900-1002-SKY. REFER TO CONTINUE CARD FOR FURTHER DETAIL.