What was found
DEEP BARE METAL GOUGE WEAR IN RH MAIN LANDING GEAR DOOR ON THE AFT OUTBOARD CORNER OF THE DOOR ADJACENT TO THE SWEEP BELT BRUSHES (C-CHECK RO 12/31/2024 - FILED OPEN) BLENDED DAMAGE ON RH MLG DOOR AT AFT OUTBOARD CORNER AND FOUND TO BE IN LIMITS IAW CRJ700 CMM 32-12-02, SRM 51-21-11, 51-25-06, 51-25-16 AND 51-42-13. NDT PERFORMED BY BARON NDT LLC, FAA CRS# 5NDR545D, REPORT# S111824-5, P.O# 174556, DATE OF INSPECTION 18NOV2024. SEE REPORT FOR DETAILS