What was found
MULTIPLE SPOTS OF CORROSION ON LH PRESSURE FLOOR SILL PANEL FS409+128 €“ 559 (C-CHECK RO 1/13/2025) BLENDED 5EA SPOTS OF CORROSION ON LH PRESSURE FLOOR SILL PANEL FS409+128 - 559 REF CRJ 200 SRM 51-21-06-00 EVALUATED BLEND AREAS 1 TO 4 ON LH PRESSURE FLOOR SILL PANEL FS409+128 - FS559 AND WERE FOUND WITHIN LIMITS OF THE SCOPE OF THIS REO AS PER REO NO 601R-53-41-666 REV. -C DATE: 2012-11-06 PARA. 1, 1.1 AND TABLE 1. MINIMUM REMAINING THICKNESS REQUIRED: 0.040'' AND THE DEEPEST POINT MEASURED: 0.040''. COMPLIED WITH ALL STEPS ON REO NO. 601R-53-41-3275 REV -- DATE 2024-12-12COMPLIED WIT SKYWEST TASK CARD 51-900-1003-SKY