What was found
LH FUEL PANEL ACCESS DOOR LANDING AT 540BB HAS 2 AREAS OF MINOR PITTING, OUTBOARD AFT EDGE APPROX. 4" TOTAL AND SEMI-CENTER FWD APPROX 1". (FILED OPEN) REPAIRED CORROSION DAMAGE ON FUEL ACCESS PANEL OPENING 540BB, OUTBOARD AFT EDGE APPROX. 4" TOTAL AND SEMI-CENTER FWD APPROX 1" WITH REFERENCE TO REO 601R-57-21-030 REV "-L" DATED 2014-02-05. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND. PERFORMED UT REMAINING THICKNESS INSPECTION WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS OF 601R-57-21-030 REV. -L, DATED 2014-02-05. PERFORMED ROTO PEEN TO THE LH WING FUEL ACCESS PANEL 540BB REWORKED AREA WITH REFERENCE TO SRM 51-24-11. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT.