What was found
OVERSIZED COUNTER-SINK LOCATED ON SKIN PANEL OF FS 202.75 BETWEEN STGR 15L AND STGR 16L REQUIRES REPAIR (FILED CLOSED) COMPLIED WITH ALL STEPS IN REO 601R-53-11-3966 REV-- DATED 2025-01-14. PERFORMED PERMANENT REPAIR TO THE FUSELAGE SKIN AND DOUBLER AT FS 202.75 BETWEEN STGR14L AND STGR17L. PERFORMED EDDY CURRENT INSPECTION ON ALL CUT LINES (STEP 3) AND PERFORMED HOLE EDDY CURRENT ROTARY PROBE INSPECTION ON INTERCOSTAL FASTENER HOLES (STEP 19) AND ALL ARE CRACK FREE. REF CP 29422887 FOR PRESSURIZATION CHECK. SEE CP29276456 FOR RVSM SKIN CONTOUR CHECK.