What was found
CORROSION FOUND ON RBL 9 AT FS1031.00 (C-CHECK RO 3/18/2025) REMOVED AND INSTALLED ALL REPAIR PARTS OF FLOOR BEAM SECTION ON RBL 9.0 BETWEEN F/S 1031 IAW CRJ 900 SRM 53-00-41-201-001-A03, COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY