What was found
MULTIPLE SMOKEING RIVETS FOUND ON LH OUTBOARD FLAP UPPER SURFACE BETWEEN WS 162.49 - WS 178.00 AND BETWEEN WS 213.08 - WS 242.00. (C-CHECK RO 03/25/2024)REMOVED AND REPLACED MULTIPLE SMOKING RIVETS FOUND ON LH OUTBOARD FLAP UPPER SURFACE BETWEEN WS 162.49 - WS 178.00 AND BETWEEN WS 213.08 - WS 242.00. COMPLIED WITH REO 601R-57-53-1305 REV -- DATED 2025-03-18. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-006 AND NDTM PART 6 53-00-096 WITH NO DEFECT FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLETED M-337.