What was found
RH WING FUEL CELL ACCESS PANE 650FB, LOWER WING PLANK ACCESS HOLE, HAS CORROSION PRESENT FROM 3 O'CLOCK POSITION TO 6 O'CLOCK POSITION. (C-CHECK RO 03/25/2024) (FILED CLOSED) BLENDED CORRODED AREA OF RH WING FUEL CELL ACCESS DOOR LANDING AT PANEL 650FB OPENING EDGE FROM 3 O'CLOCK POSITION TO 6 O'CLOCK POSITION WITH REFERENCE TO REO 601R-57-21-030 REV. -L, DATED 2014-02-05. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO CRACKS FOUND. PERFORMED UT REMAINING THICKNESS INSPECTION WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE WITHIN LIMITS OF 601R-57-21-030 REV. -L, DATED 2014-02-05. PERFORMED ROTO PEEN PROCCESS TO THE LH WING FUEL ACCESS PANEL 650FB WITH REFERENCE TO REO 601R-57-21-030 REV. -L, DATED 2014-02-05. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLIED WITH M-337. COMPLETED CORROSION FINDINGS REPORT.