What was found
UPON REMOVAL OF THE STOPPER FITTING ON THE SILL LANDING, FOUND DENTED (UPWARD AND DOWNWARD) AND CRACKED FASTENER HOLES X(2) LOCATED INBOARD AND FWD OF CARGO BAY DOOR AT FS 574.00, WL 73.00 & LBL 43.00. (C-CHECK RO 03/25/2024)PERFORMED REPAIR OF FLOOR LANDING PLATE BETWEEN FS562.72 - FS589.00 AT LBL43.00 AND WL 73.00 WITH REFERENCE TO REO 601R-53-61-8294 REV "--" DATED 2025-03-19. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6 53-00-096 WITH NO DEFECTS FOUND. COMPLIED WITH TASK CARD 51-900-1003-SKY. COMPLETED M-337.