What was found
R/H WING L/E SLAT N0.3 CENTER TRACK UPPER AND LOWER SURFACES WORN (UPPER SURFACE WORN 1.5" & 5" ABOVE ECCENTRIC PIN) (LOWER SURFACE WORN 1.5" ,5.5" & 7.5" ABOVE ECCENTRIC PIN.) (C-CHECK RO 04/30/2025)-PERFORMED BLENDOUTS ON RH WING LE SLAT #3 CENTER TRACK UPPER AND LOWER SURFACES IAW REO 670-57-42-2018 REV-- STEP 1 SHEET 10, SEE RS-01'S FOR DETAILS-PERFORMED ADJUSTMENT AND RGGING, CHECKS GOOD NO DEFECT NOTED THIS TIME REO 670-57-42-2018 REV-- PAGE 10 STEP 6-7M-337 ATTACHED-OPS CHECK GOOD NO DEFECT NOTED THIS TIME PER CRJ700 AMM 27-50-11-710-801