What was found
FOUND GOUGING DAMAGE ON FWD SIDE OF PAX DOOR HINGE DOOR SIDE AT FS320.00 (FILED CLOSED)FOUND PAX DOOR HINGE DOOR SIDE LUG AT FS 320.00 TO BE .1545" IN LENGTH, .0016" IN DEPTH, AND .0305" IN WIDTH. BLENDED GOUGING DAMAGE ON FWD SIDE OF PAX DOOR HINGE SIDE AT FS320.00 AT STGR 17L WITH REFERENCE TO SRM 51-12-00 AND REO 670-52-11-511 REV. E DATED 2017/08/02 TYPE 1. PERFORMED HIGH FREQUENCY EDDY CURRENT OF BLEND OUT ON FWD SIDE OF PAX DOOR HINGE IN REFERENCE WITH CRJ700 NDTM, PART 1, 51-20-006-250. NO CRACK INDICATIONS NOTED AT THIS TIME. PERFORMED VISUAL INSPECTION OF BLENDED LUG AND FOUND NO ADDITIONAL DAMAGE AT THIS TIME. FINISHED REWORKED AREA TO A023 AS PER SRM 51-21-16. REFERENCE CP 30218364 FOR MCO FOR DEFFERAL OF MEASUREMENT OF WALL THICKNESS.COMPLIED WITH REO 670-52-11-511 REV. "E" DATED 2017/08/02 TYPE 1. COMPLED WITH TASK CARD 51-900-1002-SKY. COMPLIED WITH M-337.