What was found
FOUND DEEP GOUGE AND DENT LENGTH 33.25'' X WIDTH 2.0'' X DEPTH 0.145'' WITH POSSIBLE STGR19L COMPROMISED LOCATED BETWEEN FR88-FR90.3 AND STGR17L-STGR21L, THIS IS CLASSIFIED AS A MAJOR REPAIR. INITIATED FORM M-337. (FILED CLOSED)COMPLIED WITH TEMPORARY REPAIR OF DAMAGE BETWEEN FR88-FR90.3 AND STGR17L-STGR21L IAW ETD2025-170-921240 REV.: A DATED 05/24/2025. COMPLETED MAJOR REPAIR FORM M-337 AND COMPLIED WITH TASKCARD 51-00-00-002-SKY-U. ALL WORK PERFORMED BY MHIRJ MRT, SEE STATEMENT OF WORK FOR INFORMATION. PER ETD2025-170-921240 REV.: A DATED 05/24/2025 THIS REPAIR MUST BE REMOVED AND DISCARDED AFTER THE FERRY FLIGHT. OPEN A NEW ETRACK FOR DAMAGES #1 AND #7 FOR THE PERMANENT REPAIR AFTER FERRY FLIGHT AND DOUBLER REMOVED. FERRY FLIGHT MUST BE PERFORMED UNPRESSURIZED.