What was found
UPON REMOVAL AND INSPECTION ON JOB HN00219316 CAMP #29599374, FOUND R/H ELEVATOR #1 L/E HINGE FITTING ASSY P/N 600-24043-1 @ ES16.52 TO HAVE PITTING CORROSION IN BEARING BORES OF BOTH HINGE HALVES. REPLACE HINGE FITTING ASSY. (C-CHECK RO 06/23/2025)INSTALLED NEW R/H ELEVATOR #1 HINGE FITTING ASSY PN 600-24043-1 LOCATED ON ELEVATOR L/E @ 16.52 REF CRJ 200 SRM 51-42-06, CRJ 200 SRM 51-42-21 AND BOMBARDIER DWG# 601R24025, REV G. COMPLIED FULLY W/SKYCARD 51-900-1003-SKY. SEE CONTINUATION SHEET FOR DETAILS.