What was found
DENT ON EXTERIOR SKIN AT FASTENER AT FS559.00 BETWEEN STGR3R - STGR4R AS MARKED (C-CHECK RO 06/23/2025) SUSPECTED DENTED AREA AT FS559.00 STGR3R-STGR4R FOUND TO BE A PREVIOUSLY BLENDED AREA. REPAIRED BLEND AREA AT FS544.00-FS559.00+16 STGR2R-STGR5R PER REO 601R-53-00-905 REV -- DATE 2025-03-25 BY CUTTING AWAY DAMAGE, FABRICATING AND INSTALLING REPAIR PARTS. SEE CONTINUATION FOR FURTHER DETAILS. LEAK CHECK GOOD. COMPLIED WITH SKYWEST TASK CARD 51-900-1003-SKY.