What was found
OVERSIZED HOLE TO FUSELAGE LOWER SKIN PANEL AT FS589.00 AT STR27 (C-CHECK RO 08/16/2025)COMPLIED WITH REO 601R-53-61-8343 REV--A DATED 2025-06-13 FOR OVERSIZED HOLE TO FUSELAGE LOWER SKIN PANEL AT FS589.00 AT STR27. PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1, 51-20-06 AND NDTM PART 6, 53-00-096 WITH NO CRACKS FOUND. PERFORMED EDDY CURRENT ROTARY PROBE INSPECTION PER NDTM PART 6, 53-00-097 AND ENSURED THE BORES THROUGH THE ENTIRE STACK UP ARE CRACK FREE. REFERENCE CP 30276658 FOR LEAK CHECK. COMPLETED TASK CARD 51-900-1003-SKY. COMPLETED M-337.