What was found
RIGHT INBD GROUND SPOILER INBD FITTING ASSY AT SPS0.00 FOUND TO BE CRACKED AT AFT LOWER FASTENER HOLE LOCATION. FABRICATED NEW RIB. REMOVED OLD AND INSTALLED NEW GROUND SPOILER RIB ASSEMBLY. COMPLIED WITH TASK CARD 51-900-1002-SKY. REF DWG# CC670-16150 REV: -F, DWG# CC670-10740 REV: -B, DWG# CC670-16200 REV: -D. SRM 51-42-21-001-001-A01; SRM 51-42-06-001-001-A01; SRM 51-42-13-001-001-A01. REV:38.