Service difficulty report · Sensor · Emb ERJ170200LR

Difficulty date
September 6, 2025
Submitted
September 8, 2025
Operation
Air carrier
Aircraft
N206SY
Make and model
Emb ERJ170200LR
Aircraft serial
17000637
Aircraft time
21,218 hours, 12,957 cycles
Part
Sensor
Part number
5912847
Part serial
6316
Condition
Faulted
Location
Flap Position
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLAP FAIL CAUTION ON APPROACH INTO BOI. FOLLOWED QRH. LANDED SUCCESSFULLY. (FLIGHT 5290 - FILED CLOSED) THIS DISCREPANCY WAS TRANSFERRED TO CAMP ITEM 30793789 WITH THE FOLLOWING CORRECTIVE ACTION: "TROUBLESHOT FLAP FAIL CAUTION MESSAGE. FOUND FAULT CODE 27512012ACE TO BE FLAGGED AND FLAPS PARTIALLY EXTENDED. CLEARED FLAP ACE 1 AND 2 INHIBITS TO RETRACT FLAPS TO ZERO. AFTER INHIBITS CLEARED FLAP LO RATE MESSAGE POPULATED FLAGGING FAULT CODE 27532003ACE. FLAP LO RATE WOULD NOT CLEAR. FLAP STATUS PAGE IN CMC SHOWED L FLAP PSU RESOLVER IN NEGATIVE AND ABOUT 3 DEGREES OFF FROM R FLAP RESOLVER. TROUBLESHOT PER FIM 27-53-00-810-815-A. PER FIM SUSPECT L FLAP PSU TO BE AT FAULT. REMOVED AND REPLACED L FLAP PSU IAW AMM 27-53-04. AFTER RIGGING FLAP LO RATE CLEARED. FLAP SYSTEM OPS CHECK MULTIPLE TIMES WITH NO FAULTS. OPS CHECK GOOD AT THIS TIME."

More about the Emb ERJ 170-200 LR