What was found
LEFT OUTBOARD FLAP. INBOARD HINGE ARM (WS178.00) HAS GOUGES ON EDGE OF HOUSING FOR SPHERICAL BEARING. REPAIRED DAMAGE ON LH OUTBOARD FLAP. INBOARD HINGE ARM (WS178.00) IN COMPLIANCE WITH REO 670-57-53-428 REV-- DATED 2025-09-26. PERFORMED EDDY CURRENT INSPECTION PER NDTM PART 1, 51-20-006 AND NDTM PART 6, 51-00-001-251-A01 WITH NO CRACKS FOUND. REFERENCE CP 30930718 FOR EDDY CURRENT INSPECTION. PERFORMED ROTO PEEN TO LH OUTBOARD FLAP, INBOARD HINGE ARM (WS178.00) REWORKED AREA WITH REFERENCE TO SRM 51-24-11. COMPLIED WITH TASK CARD 51-900-1002-SKY.