What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE: RA25822-601R-57-21-2228 952SW OP94-PR - COMPLY WITH PERMANENT REPAIR ON RA ID: 25822WHILE C/W SB 601R-57-046, PART B (R/H WING) STEP 4 (B), NDT NOTED 3 FASTENER HOLES WITH CRACKING INDICATIONS AND ONE FASTENER HOLE (AFT HOLE ON R/H MLG TRUNION STRAP). REPAIRED HOLES REF REO 601R-57-21-2228 THIS IS A SAFE LIFE REPAIR. LIFE LIMIT/DISCARD TIME DUE IN 15300 CYCLES. DUE 40201 TAC, PART NUMBER: - , SERIAL NUMBER: 7805, POSITION: (C-CHECK RO 04/16/2026)COMPLIED WITH FINAL REO 601R-57-21-4006 REV --DATE 2026-01-20, REPLACEMENT OF THE RH MLG TRUNNION AND STRAP. SEE CONTINUATION STEPS FOR DETAILS. COMPLIED WITH SKYWEST TASKCARD 51-900-1003-SKY. OPS CHECKS GOOD AT THIS TIME.