As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND GOUGED & CORRODED ON FWD CARGO SURROUND STRUCTURE S25L BETWEEN BS 533 - 581. REMOVED DAMAGE ON S25L (DOOR SILL) APPROX. BS 533 AND 581 IAW SRM 51-12-00-001-001-A01, COMPLIED WITH REO 670-53-31-1141 REV -. STEPS 1-3 AND, STEPS 8-10, STEPS 4-7. NOT APPLICABLE TO REPAIR AREA DONE ON THIS NRI. COMPLIED WITH 51-900-1002-SKY. ALL CHECKS GOOD.