What was found
RIGHT FWD EQUIPMENT BAY FLOOR WEB HAS A CRACK AFT OF DOOR. PERFORMED REPAIR ON RT EQUIPMENT BAY FLOOR WEB IAW AMM 20-70-00, SRM 550 51-42-06, SRM 51-21-11, SRM 51-25-06, SRM 51-25-16, REO 670-53-11-509, REV -E, AND REO 670-53-11-2193, REV -, NDT PERFORMED AND REMOVED AND INSTALLED ADG PUMP IAW AMM 24-23-19, & AMM 12-12-24.