What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE: RA89829-SRM 53-00-00-201-003-A01 TYPE 3-PR1 - COMPLY WITH PERMANENT REPAIR ON RA ID: 89829FOUND LIGHTNING STRIKE DAMAGE TO FUSELAGE SKIN ON THE RH SIDE AROUND A FASTENER AT FS 311.5 WL 57 GREATER THAN 0.005" DEEP. REPAIRED DAMAGED FUSELAGE SKIN ON THE RH SIDE AROUND A FASTENER AT FS 311.5 WL 57 REFERENCING APPLICABLE STEPS OF SRM 53-00-00 TYPE 3 TEMPORARY REPAIR. PERMANENT REPAIR DUE AT NEXT HEAVY CHECK, REMOVED FINISH FROM DISCREPANT AREA APPROX. FS311.5 WL57 ON RH SIDE IAW SRM 51-26-01-001-001-A01.APPLIED SEALANT AND FINISH IAW SRM 53-00-00-201-003-A01 REPAIR TYPE 3 (4)(B) 1 G AND H.REMOVED 1EA FASTENER AT DISCREPANT AREA IAW CRJ700 SRM 51-42-13-001-001-A01.INSTALLED 1EA FASTENER IAW SRM 53-00-00-201-003-A01 REPAIR TYPE 3 (4)(B) 1 E AND F.C/W ET ON FUSELAGE SKIN FS 311.5 WL 57 REWORKED AREAS IAW SRM 53-00-00-REPAIR-003-A01 STEP 5.C.4.B.1.D. NO INDICATIONS NOTEDAT THIS TIME. CALIBRATED TOOL DATA: OLYMPUS NORTEC 600 S/N 220243109 WVACT 205617 CAL DUE: 2026/10/28(908266)-TECH - CAA ET ON FUSELAGE SKIN FS 838 WL 57 REWORKED AREAS IAW SRM 53-00-00-REPAIR-003-A01.PERFORMED PRESSURE CHECK IAW CRJ-700 AMM 21-31-00-910-801-A01 - NO DEFECTS NOTED