What was found
COMPLY WITH SCHEDULED MAINTENANCE CODE: RA88272-REO 670-53-00-045-PR1 - COMPLY WITH PERMANENT REPAIR ON RA ID: 88272FUSELAGE SKIN LIGHTNING STRIKE DAMAGE. REF REO 670-53-00-045. COMPLY WITH PERMANENT REPAIR FOR REO 670-53-00-045 REV -K DATED 1/15/2021 PART 2 LIGHTNING STRIKE DAMAGE AT FASTENERS LOCATION PART B. IF DAMAGE TO RIVETS IS LESS THAN 20% OF THE RIVET HEAD AT THE FOLLOWING LOCATIONS:1. (14TH RIVET) AFT OF FS265 OF THE IB RIVET LINE ON STGR26R2. (4TH RIVET) AFT OF FS265 OF THE OB RIVET LINE ON STGR26R3. (4TH RIVET) FWD OF FS265 OF THE IB RIVET LINE ON STGR26R4. (7TH RIVET) AFT OF FS250 OF THE OB RIVET LINE ON STGR26R5. AFT EDGE OF THE (4TH RIVET) AFT OF FS250 OF THE IB RIVET LINE ON STGR26, REMOVED AND INSTALLED 5EA RIVETS AND 1EA HI-LITE IAW MHIRJ REO 670-53-00-45, DATED 2021/01/15 REV-K, PART 2 B2.APPLIED FINISH TO DISCREPANT AREA IAW CRJ900 SRM 51-25-16-001-001-A01.REMOVED FLOOR PANEL 131ALF TO ACCESS RIVET INSTALL IAW AMM 53-00-47-000-801-A01 AND SW684A.INSTALLED 131ALF IAW CRJ700 AMM 53-00-47-400-801-A01.PERFORMED PRESSURE CHECK IAW CRJ-700 AMM 21-31-00-910-801-A01 - NO DEFECTS NOTED