As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MISDRILLED LT SILL BEAM AND INBD BEAM FITTING AT 2 EA. HOLE LOCATIONS COMMON TO REAR SPAR AT LBL 36. PERFORMED REPAIR FOR MISDRILLED HOLES TO PRESSURE FLOOR STRUCTURE AT BS 797 & LBL 36 IAW SRM 51-42-21-001-001-A01,AND ALL STEPS OF REO 670-53-41-771 REV--. COMPLIED WITH TASK CARD 51-900-1002-SKY. PRESSURE CHECKED GOOD.