As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR BEAM AT LBL9 BETWEEN APPROX. FS559 - FS559+20 HAS MULTIPLE SPOTS OF CORROSION (C-CHECK RO 04/17/2026)REPAIRED FLOORBEAM AT LBL9 BETWEEN FS559 AND FS559+20 PER REO 601R-53-41-3389 REV -- DATED 2026-02-09 AND REO 601R-53-00-005 (REV B) DATED 2011-01-06. COMPLETED SKYWEST TASK CARD 51-900-1003-SKY.