What was found
RIGHT BS 280 WEB AND ASSOCIATED FASTENERS CORRODED. LOWER FS280 WEB FOUND TO BE HEAVILY CORRODED AND OUT OF ALLOWABLE LIMITS IAW SRM 53-00-00-101-001-A01. REMOVED RT BS 280 CAP ANGLE TO FOM IAW SRM 51-42-06-001-001-A01, AND SRM 51-42-13-001-001-A01. REMOVED AND CUT EXISTING SPLICE PLATE AND BS 280 BULKHEAD LOWER WEB IAW SRM 53-11-10-201-004-A01, STEPS 5B(1-3). INSTALLED SERVICEABLE CAP ANGLE IAW SRM 51-42-06-001-001-A01, SRM 51-42-13-001-001-A01. FABRICATE NEW LOWER WEB & SPLICE PLATE IAW SRM 53-11-10-201-004-A01. FABRICATED, LOCATED, & DRILLED NEW BULKHEAD LOWER WEB & SPLICE PLATE IAW SRM 53-11-10-201-004-A01, SRM 51-24-36-001-001-A01, & SRM 51-40-11-001-001-A01. INSTALLED NEW FABRICATED WEB & SPLICE PLATE IAW SRM 53-11-10-201-004-A01, STEPS 5B(4-10). INSTALLED NEW FABRICATED WEB & SPLICE PLATE IAW SRM 53-11-10-201-004-A01, STEPS 5B(4-10).