What was found
DURING ADM INSPECTION, FOUND QUARTER SIZE DENT AFT AND BELOW GROUND AIR CONNECTION DOOR, ON RHS AFT FUSLEAGE AT APPROXIMATELY BETWEEN FS605 AND FS621, BELOW WL73.50 AT APPROXIMATE BETWEEN STGR 22R TO STGR19R. PLOT, MAP, AND EVALUATE DAMAGE IF WITHIN ACCEPTABLE LIMITS OR REWORKED, ELIMINATE EVIDENCE USING STANDARD ACFT PRACTICES. COMPLIED WITH REO 601R-51-00-309 AND REO 601R-53-61-8501 AT FS 589.00 - FS 605 STRG 24R - STRG 25R