What was found
TWO CRACKS ON BS 333 BETWEEN STR 1R & 2R. INSTALLED A NEW FRAME SEGMENT BS 330 BETWEEN STR 0 - 3R IAW SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01, DWG SH670-31950 REV Y, & SB 670SH-53-002 REV C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TWO CRACKS ON BS 333 BETWEEN STR 1R & 2R. INSTALLED A NEW FRAME SEGMENT BS 330 BETWEEN STR 0 - 3R IAW SRM 51-42-21-001-001-A01, SRM 51-42-06-001-001-A01, DWG SH670-31950 REV Y, & SB 670SH-53-002 REV C.