What was found
NUMEROUS SPOTS OF CORROSION ON FUSELAGE SKIN AT ATTACHMENT HOLES FOR FAIRING PANEL 191BB. EVALUATED & REPAIRED AREAS AS REQUIRED IAW REO 601R-53-31-1372, REV --, REF CONTINUATION CARD FOR PROCEDURE DETAILS, LEAK CHECKED GOOD IAW AMM 21-50-00-863-801, NO WEIGHT CHANGE, BLEND OUT ONLY COMPLIED WITH TASK CARD 51-900-1003-SKY.