What was found
NUMEROUS SPOTS OF CORROSION ON FUSELAGE SKIN AT ATTACHMENT HOLES FOR FAIRING PANEL 192BB. EVALUATED AND REPAIRED THE AREAS IAW REO 601R-53-31-1372, REV --, & REF CONTINUATION CARD FOR PROCEDURE DETAILS, LEAK CHECKED GOOD IAW AMM 21-50-00-863-801, PRESSURIZATION LEAK CHECK, CHECKED GOOD. COMPLIED WITH TASK CARD 51-900-1003-SKY.