What was found
NUMEROUS SPOTS OF CORROSION ON FUSELAGE SKIN AT ATTACHMENT HOLES FOR FAIRING PANEL 195BB. BLENDED AND EVALUATED, FOUND WITHIN ALLOWABLE DAMAGE LIMITS IAW REO 601R-53-00-943, REV -, & SRM 53-00-31 PAR 4 B, FIG 101, & FIG 102. COMPLIED WITH TASK CARD 51-900-1003-SKY, LEAK CHECKED GOOD.