What was found
FRAME STATION 847, STRINGER 20R - CLEAT CRACKED. (C-CHECK RO 04/01/2026)FABRICATED NEW SERVICEABLE REPLACEMENT CLEAT IAW MHIRJ SNIEO SH670-35950. REMOVED CRACKED CLEAT AT FS847, STGR 20R AND INSTALLED NEWLY FABRICATED CLEAT IAW CRJ700 SRM 51-42-21-001-001-A01, 51-42-06-001-001-A01, & 51-40-11-001-001-A01. COMPLETED TASKCARD 51-9000-1002-SKY AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE. REFERENCE CONTINUATION CARD FOR WORK PERFORMED.