What was found
FRAME AT FS 364.00 STGR 23L IS CORRODED. (C-CHECK RO 08/28/2026)CUTAWAY CORRODED FRAME SECTOR AT FS364.00 STGR23L AND PERFORMED SPLICE REPAIR USING FRAME PN# 601R32007-99 IAW MHIRJ REO 601R-53-21-3816, REV--, DATED 2026-06-22. PERFORMED LEAK TEST OF REPAIRED AREA IAW SRM 51-23-01. LEAK TEST GOOD. COMPLETED AND ATTACHED TASKCARD 51-900-1003-SKY, AND MAJOR REPAIR FORM 337. NO WEIGHT CHANGE. REFERENCE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.