What was found
TWO ELONGATED HOLES FOUND IN REINFORCEMENT ANGLE AT BS 333, STR 21L. REPLACED REINFORCEMENT ANGLE AT BS 333, STRINGER 21L IAW SRM 51-42-06-001-001-A01, AND DWG SH670-31810, REV AE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TWO ELONGATED HOLES FOUND IN REINFORCEMENT ANGLE AT BS 333, STR 21L. REPLACED REINFORCEMENT ANGLE AT BS 333, STRINGER 21L IAW SRM 51-42-06-001-001-A01, AND DWG SH670-31810, REV AE.