What was found
FLOOR SUPPORT RBL 9, BTWN BS 559 - 559.00+32 CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-06, SRM 51-42-21, DWG 601R31119, REV H, & REO 601R-53-51-747, REV-. COMPLETED SKYWEST TASK CARD 51-900-1003-SKY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT RBL 9, BTWN BS 559 - 559.00+32 CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-06, SRM 51-42-21, DWG 601R31119, REV H, & REO 601R-53-51-747, REV-. COMPLETED SKYWEST TASK CARD 51-900-1003-SKY.