What was found
FLOORBEAM AT BS 280 CORRODED AT APPROX LBL 9. FLOORBEAM OUT OF LIMITS, INSTALLED A NEW LT FLOORBEAM, BS 280 IAW SRM 51-42-06-001-001-A01, SRM 51-42-13-001-001-A01, SRM 51-42-21-001-001-A01, SRM 51-42-22-001-001-A01,AND DWG CC670-34010, REV K.