What was found
AT BS 574, RBL 36 FLOOR SUPPORT HAS A SCRIBE LINE ACROSS THE TOP. INSTALLED NEW TOP CAP STRIP AT BS 574 AT APPOX RBL36 IAW SRM 51-42-06, SRM 51-42-15, AND DWG 601R35031, REV AG. FOR FASTENER CALL OUTCOMPLIED WITH TASK CARD 51-900-1003-SKY.