What was found
UPON REMOVAL OF INNER SKIN FOUND BOTTOM FWD SIDE ANGLE BS 338.963 CORRODED. REMOVED AND IINSTALLED A NEW BOTTOM FWD SIDE ANGLE BS 338.963 IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01, AND DWG 601R31702, REV N. PERFORMED PRESSURE LEAK TEST OF THE REPAIR AREA IAW AMM 21-31-00-910-801-A01. LEAK TESTED GOOD. COMPLIED WITH TASK CARD 51-900-1002-SKY. SEE CONTINUE CARD FOR WORK PERFORMED.