What was found
CRACK ANGLE AT FRAME BS 605, STR 20L. REMOVED AND REPLACED THE FRAME ANGLE AT BS 605, STR 20L IAW SRM 51-42-06, REV 39, SRM 51-42-21, REV 39, AND DWG 601R36026, REV AF. COMPLIED WITH ALL STEPS OF TASK CARD 51-900-1003-SKY LEAK CHECKED GOOD.