What was found
TRANSFER FROM EAML 1993541 TRANSFERRED FROM CAMP 33010415 IDENTIFIED A GOUGE ON LT PRESSURE FLOOR STRUCTURE PANEL AT FS549 APPROXIMATELY 12 X 132 X 003 FLIGHT 1. BLENDED SURFACE SCRATCH ON THE PAINTED LH PRESSURE FLOOR SILL STRUCTURE PANEL AT FS549 IAW SRM 51-21-06 PERFORMED UT REMAINING THICKNESS MEASUREMENT WITH REFERENCE TO NDTM PART 4 51-00-001 AND FOUND TO BE ACCEPTABLE IAW REO 601R-53-41-666 REV -C . PERFORMED EDDY CURRENT INSPECTION WITH REFERENCE TO NDTM PART 1 51-20-06 AND NDTM PART 6, 53-00-096 WITH NO CRACKS FOUND COMPLIED WITH REO 601R-53-41-666 REV C. COMPLIED WITH TASK CARD 51-900-1003-SKY